- Model
- DGWA5-ACDCBLW-24K
Item specifics
- Brand
- Deye / Solarker
- Grid AC Power
- 208V-240V/50-60HZ
- Solar DC Power Voc
- 80-380V DC(By Solar Panel)
- Solar DC Power Isc
- =20A
- Rated Cooling Capacity
- 7000(1800-7500)W
- Rated Cooling Power Input
- 2100(300-2600)W
- T1 EER (W/W)/ (BTU/W)
- 3.33/11.43
- Rated Heating Capacity
- 7000(1800-7300)W
- Rated Heating Power Input
- 2030(300-2150)W
- COP (W/W)/ (BTU/W)
- 3.45/11.82
- Compressor
- GMCC
- Refrigerant
- R410A
- MPPT Solar Controller
- Built-In
- Working Temperature
- -10 to 58℃ (T3 Tropical)
Review
Description
DGWA5-ACDCBLW-24K
Solarker Deye Solar Air Conditioner Connecting Instructions
Deye Solarker solar air conditioner use full DC inverter compressor, full DC motors, utilizes the unstable DC power generated by photovoltaic panels, does not need inverter conversion, does not need batteries or AC grid power stand by to balance, and directly supplies DC power to the compressor and motor, using VRF frequency conversion Technology, the operating frequency of the compressor and DC motor varies according to the solar panel output DC power to achieve a stable operation state.

WiFi Smart Control
WiFi and Bluetooth Remote Control
Through WiFi or Bluetooth you can connect your house air conditioner with your Android or Iphone mobile phone, and control anywhere of the devices. Owner can share devices to your family or workers and you can control multy split floor console separately or in group.
APP Power Meter Data
View real-time power generation data of solar panels and grid power consumption, daily, monthly, and annual historical power data through the APP, clearly to know how much energy saving everywhere and anytime

Hybrid ACDC Solar Features
There is many special features of Solarker hybrid ACDC solar powered air conditioner such as: AC/DC solar power meter data from APP, AC power 3 stages limitation, RS485 control.

How does Solarker/ Deye Hybrid ACDC solar powered air conditioner works
Solarker Hybrid AC/DC solar power air conditioner does not require batteries or solar inverters. Under normal daylight conditions, the DC inverter compressor is directly driven by the solar DC power generated by 3-7 solar panels to cool or heat according to the set temperature. At night or in rainy days, when the solar light is insufficient, the air conditioner will automatically calculate and obtain insufficient electricity from the grid power to work, automatically balance the grid AC and solar DC electricity, and make the system run stably throughout the day.


SVPWM Technology
2. Compressor ran below 0.1Hz
3. Operate during 50% voltage drop
Build in Solar MPPT
1. Intelligent control for detection and adjustment
2. Efficiency:99.9%
3. DC to DC 0 convert lose
4. 10+ years life design

About Installation
Hybrid AC/DC Solar AC uses a built-in MPPT booster controller, which is very easy to install. Install the indoor unit and outdoor unit just like ordinary air-conditioning installations, connect to the grid power through L/N terminal or solar panel DC power through MC4 connectors from the outdoor unit, and the air-conditioning can work normally.




Parameter
Model | / | DGWA21-ACDCBLW-09K | DGWA22-ACDCBLW-12K | DGWA5-ACDCBLW-18K | DGWA5-ACDCBLW-24K |
Power AC | Ph-V-Hz | 208V-240V/50-60HZ | 208V-240V/50-60HZ | 208V-240V/50-60HZ | 208V-240V/50-60HZ |
Voc | 80-380V | 80-380V | 80-380V | 150-380V | |
Isc | </=14A | </=14A | </=14A | </=20A | |
Cooling Capacity(T1) | W | 2700(800-3400) | 3500(800-3800) | 5150(1200-5400) | 7000(1800-7500) |
Cooling Power input(T1) | W | 680(150-1030) | 1050(150-1330) | 1510(220-1950) | 2100(300-2600) |
EER (T1) | (W/W)/ (BTU/W) | 3.85/13.20 | 3.35/11.40 | 3.40/11.60 | 3.33/11.43 |
Heating Capacity | W | 3100(900-3900) | 3900(900-4200) | 5150(1200-5300) | 7000(1800-7300) |
Heating Power input | W | 730(150-1150) | 1080(150-1300) | 1400(220-1450) | 2030(300-2150) |
COP | (W/W)/ (BTU/W) | 4.25/14.50 | 3.60/12.30 | 3.70/12.5 | 3.45/11.82 |
Compressor Brand | / | GMCC | GMCC | HIGHLY | GMCC |
Refrigerant | g | R410A(850) | R410A(850) | R410a(1220) | R410a(1600) |
Indoor unit | |||||
Dimension (W×H×D) | mm | 840×205×295 | 840×205×295 | 950×310×230 | 1080×330×237 |
Packing (W×H×D) | mm | 920×290×360 | 920×290×360 | 1045×376×326 | 1140×300×382 |
Net weight/Gross weight | Kg | 9.5/11.8 | 9.5/11.8 | 12.0/14.5 | 15.0/17.5 |
Outdoor unit | |||||
Dimension (W×H×D) | mm | 802×564×323 | 802×564×323 | 802×564×323 | 900×700×337 |
Packing (W×H×D) | mm | 910×622×405 | 910×622×405 | 910×622×405 | 1006×755×418 |
Net/Gross weight | Kg | 30.0/34.0 | 30.0/34.0 | 35.5/40.0 | 46.0/51.0 |
DC Inverter Air Conditioner Features

Twin Rotay DC Inverter Compressor
High Efficiency, low noise level, stable working, longer life design. Powerful Cooling.

Low Noise DC Motor
DC fan motor, higher efficiency and accurate control

Golden Fin Evaporator and Condenser
Golden Fin is more resistant to oxidation and corrosion than ordinary blue fins of most

WiFi Remote Control
WIFI connection to the air conditioner and control anywhere and anytime through mobile APP

Wide Grid AC Voltage
With DC inverter compressor and the self-developed electronic control system, the air conditioner can be started and operated normally under a voltage between 130 and 280V in order to solve the problem of unstable voltage

Fault Code Indicate
When the machine operates with problems, display section will show the corresponding fault code to make after -sales service convenient and prompt.

Labyrinth PCB Cooling Radiator
Outdoor inverter electric control box uses labyrinth design, and proved by 2H rainstorm simulation test, it won’t get wet even in the typhoon day

5VA security controller Box
The highest level of fire-proof materials are adopted to protect the internal electronic control components, and prevent fire due to internal and external factors upon an accident.

Dual Side Water Outlets
The water outlet can be installed on either left or right side of the water tray for your convenience. connector to control the unit.

Environmentally Friendly Refrigerant
R32 or R410A refrigerant can be selected

58℃ Tropical Temperature Working
T3 System, High EER level design, the unit works under 58 degree middle east tropical temperature

EEV Accurate Refrigerant Control